
第6章中断控制器( INTC ) ........................................... ................... 77
6.1
6.2
6.3
产品特点.............................................................................................................................77
输入/输出引脚..............................................................................................................79
注册说明........................................................................................................79
6.3.1中断控制寄存器1 ( ICR1 ) ........................................ ............................. 80
6.3.2中断控制寄存器2 ( ICR2 ) ........................................ ............................. 82
6.3.3 IRQ状态寄存器( ISR ) ......................................... ........................................... 84
6.3.4中断优先级寄存器A至J ( IPRA到IPRJ ) .................................... ........... 85
中断源...............................................................................................................87
6.4.1外部中断............................................. .................................................. 87
6.4.2片上外围模块中断......................................... ....................... 88
6.4.3用户断点中断............................................ ................................................ 88
6.4.4 H- UDI中断...................................................................................................89
中断异常处理向量表............................................. ..................... 90
Operation...........................................................................................................................93
6.6.1中断序列............................................. .................................................. 93
中断异常处理后的6.6.2堆栈.......................................... ................ 95
中断响应时间...................................................................................................96
数据传输与中断请求信号............................................ ....................... 98
6.8.1处理中断请求信号的来源为DTC激活和
CPU中断,但不DMAC激活........................................... ............... 99
6.8.2处理中断请求信号的来源进行激活DMAC ,
但不是CPU中断和DTC激活........................................... ............. 99
6.8.3处理中断请求信号源的DTC激活,
但不是CPU中断和DMAC激活........................................... ......... 99
6.8.4处理中断请求信号源为CPU中断
但不是DMAC和DTC激活............................................ ....................... 100
6.4
6.5
6.6
6.7
6.8
第7用户中断控制器(UBC ) .......................................... ................. 101
7.1
7.2
产品特点.............................................................................................................................101
注册说明........................................................................................................103
7.2.1用户断点地址寄存器( UBAR ) ........................................ ........................ 103
7.2.2用户断点地址屏蔽寄存器( UBAMR ) ....................................... ............ 103
7.2.3用户断点总线周期寄存器( UBBR ) ....................................... ...................... 104
7.2.4用户中断控制寄存器( UBCR ) ........................................ .......................... 105
Operation...........................................................................................................................106
7.3.1流动用户断点运行.......................................... ................................... 106
7.3.2中断的片上存储器取指令周期...................................... ..... 108
7.3.3程序计数器(PC )值保存........................................ ........................... 108
使用的例子...............................................................................................................109
Rev.4.00 2008年3月27日,第四十四页的喜
REJ09B0108-0400
7.3
7.4