12通道/ 8通道EEPROM可编程
系统管理器,提供非易失故障寄存器
MAX16046/MAX16048
表2.输入监视范围和启用
注册/
EEPROM
地址
位范围
描述
MON1电压范围选择:
00 = 0 5.6V在5.46mV步骤
01 = 0 2.8V在2.73mV步骤
10 = 0 1.4V在1.36mV步骤
11 = MON1不转换或者监视
MON2电压范围选择:
00 = 0 5.6V在5.46mV步骤
01 = 0 2.8V在2.73mV步骤
10 = 0 1.4V在1.36mV步骤
11 = MON2不转换或者监视
MON3电压范围选择:
00 = 0 5.6V在5.46mV步骤
01 = 0 2.8V在2.73mV步骤
10 = 0 1.4V在1.36mV步骤
11 = MON3不转换或监控
MON4电压范围选择:
00 = 0 5.6V在5.46mV步骤
01 = 0 2.8V在2.73mV步骤
10 = 0 1.4V在1.36mV步骤
11 = MON4不转换或者监视
MON5电压范围选择:
00 = 0 5.6V在5.46mV步骤
01 = 0 2.8V在2.73mV步骤
10 = 0 1.4V在1.36mV步骤
11 = MON5不转换或者监视
MON6电压范围选择:
00 = 0 5.6V在5.46mV步骤
01 = 0 2.8V在2.73mV步骤
10 = 0 1.4V在1.36mV步骤
11 = MON6不转换或者监视
MON7电压范围选择:
00 = 0 5.6V在5.46mV步骤
01 = 0 2.8V在2.73mV步骤
10 = 0 1.4V在1.36mV步骤
11 = MON7不转换或者监视
MON8电压范围选择:
00 = 0 5.6V在5.46mV步骤
01 = 0 2.8V在2.73mV步骤
10 = 0 1.4V在1.36mV步骤
11 = MON8不转换或者监视
[1:0]
[3:2]
0Fh
[5:4]
[7:6]
[1:0]
[3:2]
10h
[5:4]
[7:6]
______________________________________________________________________________________
17