1997年12月16日
45
飞利浦半导体
表11
通过初始化指令, 4位接口。不适用于我
2
C总线操作
LCD控制器/驱动器
步
上电或未知状态
|
等待V后2毫秒
DD
上升超过V
POR
|
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 0; DB5 = 1; DB4 = 1
|
等待2毫秒
|
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 0; DB5 = 1; DB4 = 1
|
等待40
s
|
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 0; DB5 = 1; DB4 = 1
|
|
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 0; DB5 = 1; DB4 = 0
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 0; DB5 = 1; DB4 = 0
RS = 0 ; R / W = 0; DB7 = N; DB6 = M ; DB5 = 0; DB4 = 0
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 0; DB5 = 0; DB4 = 0
RS = 0 ; R / W = 0; DB7 = 1; DB6 = 0; DB5 = 0; DB4 = 0
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 0; DB5 = 0; DB4 = 0
RS = 0 ; R / W = 0; DB7 = 1; DB6 = 0; DB5 = 0; DB4 = 0
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 0; DB5 = 0; DB4 = 0
RS = 0 ; R / W = 0; DB7 = 0; DB6 = 1; DB5 = I / D ; DB4 = S
|
初始化结束
描述
BF不能在此指令之前进行检查。 “功能设置”
(接口为8位长) 。
BF不能在此指令之前进行检查。 “功能设置”
(接口为8位长) 。
BF不能在此指令之前进行检查。 “功能设置”
(接口为8位长) 。
BF后,可以按照以下说明进行检查。当BF没有被选中时,
指令之间的等待时间的特定网络连接编辑指令的时间(见表3)。
“功能设置” ( Set接口到4位长) 。接口是8位长。
“功能设定” (接口是4位长) 。
指定的显示线和电压发生器的特征数目。
“显示关闭” 。
“清除显示” 。
“进入模式设置” 。
产品speci fi cation
PCF2104x